Trigger input. (A normally-open potential-free input) Momentarily
connecting this input to COM will cause the gate to open or close
depending on the operating mode selected. For more information see the
Autoclose feature and Modes of Operation
PED
Pedestrian opening input. (A normally-open potential-free input).
Momentarily connecting this input to COM will cause one gate to open to
the Pedestrian open position. For more information refer to the Pedestrian
feature
FRX
Free-exit input. (A normally-open potential-free input). Momentarily
connecting this input to COM will cause a gate which is closed, or closing,
to open or re-open. If the gate is open, or opening, the signal has no
effect other than to reset the Autoclose timer (if selected). Free-exit (FRX)
never initiates a closing cycle. The only way to close a gate, if only the
FRX input is used, is to activate the Autoclose feature on the controller
LIT
LIT Activates the pillar light output. (A normally-open potential-free input).
Momentarily connecting this input to COM will cause the LIGHT relay to
energize for a period of time as set in the courtesy light timer menu. If the
connection is made for a period exceeding 3 seconds the pillar light relay
will latch and remain latched indefinitely until a new momentary
connection to COM is given.
LED
External gate status indicator. (A low current output signal.) An output
terminal which provides a low current drive (approx. 4,5V DC, 20mA) to a
LED which can be used to indicate the gate status remotely. If more than
three LEDs are required it is necessary to fit the CP78 MULTI LED driver
card. For more details on the feedback about the status of the gate
provided by the STATUS LED refer to pg 43
Com
The COMMON termination point. All trigger signals etc. have their return
path to one of the COM terminals.
Aux 12V
Auxiliary power connection. Provides a +12V DC supply for auxiliary
equipment such as a radio receiver, photo cells, etc. It is linked directly to
the battery positive via a 3A resettable fuse.
Safe Com
Used for switching the power supply to the safety beams. If automatic
beam testing is required, the negative power supply connection of the
beam transmitters and receivers must be wired to this point
Sol
Solenoid strike or Magnetic lock. A solenoid strike lock or Magnetic lock
can be connected between 12V and SOL. Note that the maximum current
draw allowed for the lock is 2A. Should the solenoid lock or magnetic lock
exceed this current rating it is necessary to use an interposing relay
Particularly with magnetic locks, ensure that the steady state
current draw calculated over a 24 hour period and added to this,
the quiescent current draw of the controller, other peripherals and
the usage of the motors, does not exceed the current delivered
by the charger. If necessary, fit a separate supply to power the
lock using an interposing relay connected to the Sol input.