25. Diagnostics

Diagnostic LEDs

The controller is fitted with diagnostic lights (LEDs) that assist with the set-up and
maintenance of the gate.
Table 2 below provides a description and purpose of the indicator lights with Figure 71
alongside, indicating the location on the control
M Sens1
M Sens2
Sens+
Sens-
Safe CLS
Safe OPN
Com
LCK/STP
TRG
PED
Com
FRX
LIT
LED
Com
Aux 12V
Safe Com
Sol
Light
Gate status LED
Slow regular flash
Fast regular flash
One flash every two seconds
Two flashes every two seconds
Three flashes every two seconds
Four flashes every two seconds
Four flashes every two seconds
FIGURE 71
Gate is opening
Gate is closing
Courtesy Light latched on
Mains Failure
Battery Low
Collision Shutdown
Multiple Collisions have occurred
Page 61
Safety close
On when the closing beam is not activated
Off when closing safeties obstructed
Safety open
On
when the opening beam is not activated
Off when opening safeties obstructed
Lck/Stp
On
when system ready to operate
Off when system locked
Trg
On
when the trigger signal is present
Off when no signal
Ped
On
when the pedestrian signal is present
Off when no signal
FRX
On
when a free-exit signal is present
Off when no signal
Lit
On
when signal present
Off when no signal
LED
On when gate open
Off when gate closed