Maintenance Schedule

Monthly

(or quarterly depending on experience with individual cellar)
 Check filter and drain trap – clean if needed.
 Check for noise or vibration.
 Check for short-cycling of the unit – a turning on and off of the compressor unit
more than either (8) times/hour.

Yearly

(in addition to monthly)
 Replace filters if worn or plugged beyond cleaning.
 Check evaporator and condenser coils for dirt – use a vacuum with a brush
attachment to clean the coils.
 Clean condensate pan under the evaporator coil by flushing. Be careful to keep the
drain pans clear of any and all debris.
 Inspect cabinet for corrosion or rusting – clean and paint.
 Inspect for dirt buildup on or inside the unit. Clean unit by vacuuming or wiping it
down.
 Check for loose insulation, fasteners, gaskets or connections.
 Check the wiring connections and integrity or cords.
 Examine ducts for any cracks or breach.
 Check fan and solenoid on humidifier.
 Replace humidifier pad (if used).