Time Code Presetting Procedure - JVC GY-DV5001 Instructions Manual

Dv camcorder
Table of Contents

Advertisement

TIME CODE PRESETTING PROCEDURE

EDITSEARCH
FILTER
1
3200K
2
5600K
1 8
/
ND
.3
5600K
.4
5600K
1 64
/ ND
STATUS
SHUTTER
MENU
AUTO IRIS
FULL AUTO
BLACK
LOLUX
BACK L
STRETCH
NORMAL
NORMAL
SPOT L
COMPRESS
POWER
VTR
ON
OFF
SHUTTER dial
STATUS button
TOP MENU screen
––– MENU –––
CAMERA OPERATION..
CAMERA PROCESS..
AUDIO..
LCD/VF..
TC/UB/CLOCK..
OTHERS..
FILE MANAGE..
MENU ALL RESET
EXIT
TC/UB/CLOCK menu screen
––– TC/UB/CLOCK –––
TC PRESET
TC CLEAR
UB PRESET
UB CLEAR
UB REC
HEADER REC..
TIME/DATE..
PAGE BACK
Time code (hour, min, sec, frame)
PRESETTING USER'S BIT DATA
––– TC/UB/CLOCK –––
TC PRESET
TC CLEAR
UB PRESET
UB CLEAR
UB REC
HEADER REC..
TIME/DATE..
PAGE BACK
Align the cursor with UB
Zero-resetting the Time Code or User's Bit Data
This is performed with the CLEAR item on the TC/UB/CLOCK menu screen. (Performed separately for the time code and the
user's bit data.)
1 Rotate the SHUTTER dial to align the cursor ( ) with the CLEAR item, and then press the SHUTTER dial.
2 Rotate the SHUTTER dial to select EXECUTE as the setting value, and then press the SHUTTER dial.
OPEN
MONITOR
LCD BRIGHT
DISPLAY
AUDIO
LEVEL
PULL
OPEN
FRONT
REAR
CH-1
CH-2
CH-1
CH-2
MODE
AUDIO INPUT
AUDIO SELECT
VTR
CH-1
CH-2
AUTO
CAM
MANUAL
CANCEL
00:00:00:00
EXECUTE
CANCEL
00 00 00 00
EXECUTE
CANCEL
ON
00:00:00:00
EXECUTE
CANCEL
00 00 00 00
EXECUTE
CANCEL
ON
10. TIME CODE OPERATION
The time code and user's bit data are preset on the TC/UB/
CLOCK menu screen.
1.
Display the TC/UB/CLOCK menu screen.
1 Press the Status button for 1 second or more to display
the TOP MENU screen.
2 Rotate the SHUTTER dial to align the cursor ( ) with
the TC/UB/CLOCK item, and then press the SHUTTER
dial.
● The TC/UB/CLOCK menu screen appears.
2.
Set the time code (hours, minutes, seconds, frames).
1 Rotate the SHUTTER dial to align the cursor ( ) with TC
PRESET, and then press the SHUTTER dial.
● The first digit of the time code blinks.
The blinking digit is the one to be set.
2 When the SHUTTER dial is pressed, the blinking digit
changes.
3 When the SHUTTER dial is rotated, the value of the
blinking digit changes.
When the SHUTTER dial is rotated upward, the value
becomes higher. When rotated downward, the value
becomes smaller.
4 Repeat the procedure described in 2 and 3 above to
set the desired value for all digits.
5 After setting the frame digit, press the SHUTTER dial to
make EXECUTE blink. The setting values are confirmed
when the SHUTTER dial is pressed again.
To cancel the setting, select CANCEL and press the
SHUTTER dial.
3.
When all the digits are set.
● Press the STATUS button to return to the normal screen
or
● Rotate the SHUTTER dial to align the cursor ( ) with the
PAGE BACK item, and then press the SHUTTER dial to
return to the TOP MENU screen.
The user's bit data are preset with the UB PRESET item on the
TC/UB/CLOCK menu screen.
The method for setting is the same as the method for setting
the time code described above.
● The user's bit can be specified using numerals or alphabetic
letters from 0 to F for each digit.
● To record user's bit data, set the UB REC item to ON.
CAUTION:
It is not possible to set all the digits of the user's bit data to
"F". Reading of the data during playback will not be possible
for an all-F setting.