Time Code Presetting Procedure; Presetting User's Bit Data; Recording Time Codes In Continuation Of Time Codes Recorded On Tape - JVC GY-DV500E - Pal Professional Dv Camcorder Instructions Manual

Dv camcorder
Hide thumbs Also See for GY-DV500E - Pal Professional Dv Camcorder:
Table of Contents

Advertisement

TIME CODE PRESETTING PROCEDURE (for U-ver.)
2.
4.
HOLD button
SHIFT button
CH-1
AUDIO
CH-2
TC GENERATOR
LEVEL
CH-1
CH-2
PRESET
FREE
AUTO
REGEN
REC
MANUAL
AUDIO SELECT
AUDIO INPUT
CH-1
CH-2
CONTINUE
MENU
FRONT
REAR
LITHIUM BATT.
GROUP
ITEM
SELECT
DATA SET
HOLD
SHIFT
ADVANCE
PRESET
6.
3.
ADVANCE
PRESET
button
button
HOLD
H
M
S
F
HOLD
H
M
S
F
HOLD
H
M
S
F
HOLD
H
M
S
F
TIME CODE PRESETTING PROCEDURE (for E-ver.)
2.
4.
HOLD button
SHIFT button
CH-1
AUDIO
CH-2
TC GENERATOR
CH-1
CH-2
LEVEL
PRESET
FREE
AUTO
MANUAL
REGEN
REC
AUDIO SELECT
AUDIO INPUT
CH-1
CH-2
CONTINUE
MENU
FRONT
REAR
LITHIUM BATT.
GROUP
ITEM
SELECT
DATA SET
HOLD
SHIFT
ADVANCE
PRESET
6.
3.
ADVANCE
PRESET
button
button
HOLD
H
M
S
F
HOLD
H
M
S
F
HOLD
H
M
S
F
HOLD
H
M
S
F
9. TIME CODE OPERATION
1.
Display the time code on the counter display.
Set the COUNTER switch to "TC".
• Time code up to 23 hrs. 59 min. 59 sec. 29 frames can be
preset.
2.
Place the time code generator in preset mode.
Press the HOLD button.
• The "HOLD" indicator lights on the display to indicate
the preset mode. The first digit of the counter display
blinks.
3.
Set the value of the blinking digit.
Press the ADVANCE button.
• The value of the blinking digit changes.
4.
Change the blinking digit.
Press the SHIFT button.
• The blinking digit changes.
5.
Set the desired value for all digits.
Repeat steps 3. and 4. for each digit.
6.
Preset the set data in the memory.
Press the PRESET button.
• The set data is saved as the time code generator value.
Following the above operation, the "HOLD" indicator
disappears from the display, the counter stops blinking
and the time code is preset.
• If the REC/FREE switch is set to FREE, the time code
starts to run.
If you preset a wrong time code, perform steps 2 . 3 . 4 . 5. and
6. again.
1.
Display the time code on the counter display.
Set the COUNTER switch to "TC".
• Time code up to 23 hrs. 59 min. 59 sec. 24 frames can be
preset.
2.
Place the time code generator in preset mode.
Press the HOLD button.
• The "HOLD" indicator lights on the display to indicate
the preset mode. The first digit of the counter display
blinks.
3.
Set the value of the blinking digit.
Press the ADVANCE button.
• The value of the blinking digit changes.
4.
Change the blinking digit.
Press the SHIFT button.
• The blinking digit changes.
5.
Set the desired value for all digits.
Repeat steps 3. and 4. for each digit.
6.
Preset the set data in the memory.
Press the PRESET button.
• The set data is saved as the time code generator value.
Following the above operation, the "HOLD" indicator
disappears from the display, the counter stops blinking
and the time code is preset.
• If the REC/FREE switch is set to FREE, the time code
starts to run.
If you preset a wrong time code, perform steps 2 . 3 . 4 . 5. and
6. again.
9. TIME CODE OPERATION

PRESETTING USER'S BIT DATA

RESET button
OPERATE/WARNING
CH 1
RESET
40 30
20
CH 2
32k
48k
MONITOR
AUD LOCK
SP
SELECT
MENU
REMAIN
H
• Pressing the RESET button in the preset mode resets
the time code or user's bit data to 00 00 00 00.
• If you press the HOLD button by mistake, press the HOLD
button once more to return to the previous display.

9-3 Recording Time Codes in Continuation of Time Codes Recorded on Tape

The GY-DV500 also incorporates a time code reader. Therefore, when the unit enters record mode from record-pause mode, it can
read the time code data recorded on the tape and record time codes in continuation of the existing data. The recorded user's bit
data is identical to the user's bit data recorded on tape.
* However, approximately ±1-frame variations may occur in scene transition accuracy.
To enable this, set the time code related switches as follows before starting recording.
CH-1
AUDIO
CH-2
LEVEL
CH-1
AUDIO SELECT
AUDIO INPUT
CH-1
LITHIUM BATT.
57
58
Display user's bit data on the counter display and perform
the same procedure as the time code presetting procedure.
• The user's bit can be specified using numerals or alphabetic
letters from 0 to F for each digit.
LIGHT
OVER
AUTO OFF DEW
ON
10
0 dB
OVER
SERVO
RF
L i
OFF
PB
NDF
HOLD
Note:
COUNTER
H
M
S
F
CTL
E
BATT
F
REV FWD
Do not specify F in the user's bit data.
TC
UB
M
Specification of F results in a special setting and reading
of user's bit data during playback may become impossible.
If all user's bit digits are set to F, the data cannot be read.
PRESET/REGEN switch
Setting
TC GENERATOR
CH-2
Set the VCR Setup Menu item No. 516 DISPLAY SELECT to
PRESET
FREE
AUTO
REGEN
REC
MANUAL
"TC".
See page 69.
CH-2
CONTINUE
MENU
FRONT
REAR
Set the counter display to show time codes or user's bit data.
GROUP
ITEM
SELECT
DATA SET
HOLD
SHIFT
ADVANCE
PRESET
Set the PRESET/REGEN switch to REGEN.
• The time code run mode becomes unrelated to the REC/
FREE switch settings.
• The time code framing mode automatically becomes the
mode (drop frame or non drop frame) already recorded on
the tape.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gy-dv500

Table of Contents