6. Align the LED window of the filter with the holes for the LEDs on the bezel
7. Align the air-filter retainer over the filter with the ball-stud clips facing down
8. Gently push the air-filter retainer down until it snaps into the ball-stud
9. Install the bezel on the front of the system (see "Installing the bezel assembly"

Removing and installing power modules

The BladeCenter T unit is separated into two power domains. To support devices
in power domain B, a power-supply module option (consisting of two power
modules) must be installed.
The following table summarizes the modules that are powered by each power
domain.
Ball-stud clips
LED pipes
LED window
Ball-studs
LED holes
and lay the filter into the bezel frame.
and the LED light pipe lined up with the LED holes on the bezel.
fasteners on the back of the bezel.
on page 41 for instructions).
Power domain
Power-module bays
A
B
Modules powered by the power domain
1 and 2
I/O-module bays 1 and 2
Management-module bays 1 and 2 Media
tray Blade bays 1 through 4
3 and 4
Blade bays 5 through 8 I/O-module bays 3
and 4
Chapter 4. Setting up the BladeCenter T hardware
Air-filter retainer
Air-filter
Bezel
43