Bladecenter T Unit Power, Controls, And Indicators - IBM BladeCenter T Hardware Maintenance Manual And Troubleshooting Manual

Type 8267
Hide thumbs Also See for BladeCenter T:
Table of Contents

Advertisement

v Serial connector: The LAN module provides one DB60 serial connector (female)
I/O modules
You can install a maximum of four I/O modules at the rear of the system (a
maximum of four Gigabit Ethernet switches, or a maximum of two Gigabit
Ethernet switches and two Fibre Channel switches). The minimum system
configuration requires one Gigabit Ethernet switch or pass-thru module. The I/O
switch modules provide high-performance connectivity between the blade servers.
See the documentation that comes with each I/O module for a description of the
LEDs and connectors on the I/O module.

BladeCenter T unit power, controls, and indicators

This section describes the controls and light-emitting diodes (LEDs) and how to
start and shut down the BladeCenter T unit.
The network management station, through these connectors, can access control
functions running in the management module, the service processor on each
blade server, or within each switch module. However, it cannot use these ports
to communicate with application programs running in the blade servers. The
network management station must direct those communications through a
network connected to the external ports in the I/O modules in the BladeCenter
T unit.
for direct serial connection to each blade server using an external serial breakout
cable (IBM part number 40K9605).
RJ-45
connector
TOP
D
2
1
2
4
BTM
E
Standard Ethernet
cable
Connect directly to PC
LAN module
TOP
D
MJR
CRT
MNR
1
3
192.168.70.135
BTM
E
Connect through an Ethernet switch
192.168.70.125
192.168.70.155
Standard
Ethernet
cables
Ethernet switch
Chapter 1. General information
15