Temperature error messages
Note: See Chapter 7, "Parts listing, BladeCenter T Type 8267," on page 101 to determine which components should
be replaced by a field service technician.
Message
Power supply x temperature fault
Power supply x temperature warning
Switch x temperature fault
System over abbient temperature
Switch x temperature fault
Blower error messages
Note: See Chapter 7, "Parts listing, BladeCenter T Type 8267," on page 101 to determine which components should
be replaced by a field service technician.
Message
Blower x outside recommended speed
Blower x failure
Blower x fault
Power error messages
Note: See Chapter 7, "Parts listing, BladeCenter T Type 8267," on page 101 to determine which components should
be replaced by a field service technician.
Message
Power module 3 or 4 is required to power
blades 5 to 8
Power supply x fault
Power supply x 12V over voltage fault
Power supply x 12V over current fault
Power supply x 12V under voltage fault
Power supply x 12V current fault
Power supply x removed
94
BladeCenter T Type 8267: Hardware Maintenance Manual and Troubleshooting Guide
Action
1. Make sure that the system is being properly cooled; see "System
reliability considerations" on page 36.
2. Replace power supply x.
1. Make sure that the system is being properly cooled; see "System
reliability considerations" on page 36.
2. Replace power supply x.
1. Make sure that the system is being properly cooled; see "System
reliability considerations" on page 36.
2. Replace switch x.
Make sure that the system is being properly cooled; see "System
reliability considerations" on page 36.
Make sure that the system is being properly cooled; see "System
reliability considerations" on page 36.
Action
Replace blower x.
Replace blower x.
Replace blower x.
Action
Make sure that power modules 3 and 4 are installed and connected
to power.
Replace power module x.
Replace power module x.
1. An over current condition is typically caused by an external load
fault. Attempt to restart the faulted power module by removing
power to the system components one at a time to isolate the
failing component.
2. Replace power module.
Replace power module x.
Replace power module x.
Reinstall power supply x.