Recirc/Spray Valves - Graco EnergyComplete 313221H Instructions - Parts Manual

Table of Contents

Advertisement

Recirc/Spray Valves

1. See Before Beginning Repair, page 33. Relieve
pressure, page 21.
2. See F
. 8. Disassemble Recirc/Spray valves. Clean
IG
and inspect all parts for damage. Ensure that the
seat (503a) and gasket (503b) are positioned inside
each valve cartridge (503).
3. Apply PTFE pipe sealant to all tapered pipe threads
before reassembling.
4. Reassemble in reverse order, following all notes in
F
. 8.
IG
34
506
502
501
509
507
508
1
Torque to 250 in-lb (28 N•m).
2
Use blue threadlocker on valve cartridge threads into manifold.
3
Part of item 503.
F
. 8. Recirc/Spray Valves
IG
Repair
505
504
503
1
2
503a
3
503b
3
510
r_256765_313221_b_7b
313221H