9.
When nearly clear solvent comes from recircula-
tion tubes, set function knob to Stop/Park
Place recirculation tubes in solvent pails.
10.
Set function knob to Fast Recirc
solvent through system for 10-20 minutes to
ensure thorough cleaning.
To flush gun, refer to gun instruction manual.
Purge Gun Hoses
Disconnect hoses from gun and secure back
into the tanks for thorough cleaning with sol-
vent.
Turn Recirc/Spray valve A to Spray.
Open gun into waste container A.
Set function knob to Slow Recirc
hose is flushed.
Set function knob to Stop/Park
Repeat for B side.
11.
Set function knob to Stop/Park
24
12.
Solvent flushing is a two step process. Go back
to step 4, drain solvent, and flush again with
.
fresh solvent.
13.
Leave unit filled with solvent or reprime with new
material.
Never leave the unit dry unless it has been disassem-
bled and cleaned. If fluid residue dries in the pumps,
. Circulate
the ball checks may stick the next time you use the
unit.
until
.
.