9.
Fill Wet-Cups
Keep the felt washers in the pump wet-cups saturated
with Graco ISO pump oil, Part No. 217374. The lubricant
creates a barrier between the red fluid and the atmo-
sphere.
Pump rod and connecting rod move during opera-
tion. Moving parts can cause serious injury such as
pinching or amputation. Keep hands and fingers
away from wet-cup during operation. Shut off Motor
Power
before filling wet-cup.
Fill wet-cups through
slots in plate, or loosen
screws and swing plate
aside.
10.
Install suction tube
NOTICE
To prevent cross-contamination of fluids and equip-
ment parts, never interchange component A and
component B parts or containers.
Label one pail "A" and the other "B", using the labels
provided. Always doublecheck which material you
have before placing suction tubes in pails.
Using a drill and mixing blade, mix filled or sep-
arated materials in the pail. Material left in the
pails overnight may need to be remixed.
313221H
a.
Open red and white fluid pails and posi-
tion in front of suction tubes.
b.
Stand behind unit and hold crossbar.
Lean unit backwards until the suction
tubes are above the supply pails.
A
B
c.
Place suction tubes in pails.
A
B
Cut portion of the pail's lid for suction tube and
assemble on pail to prevent debris from entering
pumps.
Setup
r_256765_313221_b_12
r_256765_313221_b_17