Spraying/Dispensing

Air is supplied to spray gun with gun piston
safety lock and gun fluid manifold valves A
and B closed (if present).
1.
Set function knob to Stop/Park
2.
Set Recirc/Spray valves to Spray.
3.
Turn function knob to Pressure Adjust
Keep turning to the right until fluid pressure
gauges show desired pressure.
313221H
4.
Check fluid pressure gauges to ensure proper
pressure balance. If imbalanced, reduce pres-
sure of higher component by slightly turning
Recirc/Spray valve for that component toward
Recirc, until gauges show balanced pressures.
The pressure imbalance alarm (Status Code 1)
is inactive for 10 sec after entering spray pres-
sure mode, to allow time to balance pressures.
Watch gauges for 10 sec to be sure pressure
.
holds on both sides and pumps are not mov-
ing.
5.
Open gun fluid manifold valves A and B
(impingement mix guns only).
On impingement guns, never open fluid mani-
fold valves or trigger gun if pressures are
imbalanced.
.
6.
Disengage piston safety lock.
7.
Test spray onto cardboard or plastic sheet. Ver-
ify that material fully cures in the required length
of time, and is the correct color. Adjust pressure
and temperature to get desired results. Equip-
ment is ready to spray.
Spraying/Dispensing
In this example, B side
pressure is higher, so
use the B side valve to
balance pressures.
19