11.
Mount pails
a.
Insert pail handles on mounting bracket
(G).
G
A
12.
Purge air and flush fluid from lines
a.
Remove both recirculation tubes (N)
from the pails and secure each one in a
dedicated waste container (W).
A
B
b.
Set function knob to Stop/Park
c.
Plug in power cord(s). See T
page 13.
16
B
r_256765_313221_b_18
N
W
r_256765_313221_b_19
2,
ABLE
d.
Turn on Motor Power.
e.
Set Recirc/Spray valves to Recirc.
f.
Set function knob to Slow Recirc
Fast Recirc
g.
When clean fluids exit both recirculation
tubes (P), set function knob to
Stop/Park
h.
Replace recirculation tubes in pails.
.
Preheat hoses if ambient temperature is
below 70°F (43.3°C) or continue with Startup,
page 18.