INSTALLATION CHECK-OUT, CONDENSER - Continued:
____
____
Are exposed terminals/connections protected with an anti-corrosive coating?
____
____
I
____
____
Is condenser properly grounded to the chassis?
EVAPORATOR AREA:
YES
NO
____
____
Is evaporator(s) mounted securely to the bus roof? Either through the roof using
hardware supplied by Carrier Transport Air Conditioning or by Carrier Transport Air
Conditioning approved OEM supplied mounting brackets?
____
____
If evaporator is mounted with carriage bolts through the roof, are the roof rails
and bolts tight and sealed with caulking?
____
____
Are refrigeration hoses routed properly? In hose covers or in the skin of the bus.
Hose Covers must never cover Bus windows.
____
____
Are two drain lines installed and running to opposite sides of the bus?
____
____
Are drain lines running downhill?
____
____
Are condensate valves (Kazoos) installed on drain line outlets?
____
____
Is suction fitting and block valve (TXV) wrapped with "no-drip" tape to prevent
condensate drip?
____
____
Is suction hose covered with insulation to prevent condensate drip?
____
____
Are blowers/fans running in the proper direction? Through evaporator filter and pushing
into the
____
____
Are evaporators properly grounded? Evaporator must be grounded on the nearest vehicle
chassis rail using the ground wire (8 Gauge) supplied with installation kit.
____
____
If ducted system, is ductwork properly mounted and trimmed?
____
____
Are all required grills/louvers installed in the ductwork?
REFRIGERATION HOSE AND ELECTRICAL HARNESS ROUTING:
YES
NO
____
____
Is system wiring harnesses and refrigerant hoses protected from sharp edges, heat sources
and moving parts? Refrigerant hoses and harnesses must be protected from heat sources,
sharp edges and moving parts.
____
____
Are insulated clamps used to support the hose and harness? Refrigerant hose should be
supported with insulated clamps wherever possible. Tie-wraps should only be used to bundle
together wiring and hose assemblies.
________
T--311
f and when needed, is condenser(s) protected from road
passenger compartment.
Are the "Quick-Click" fittings properly clamped to the "Quick-Click" hose?
-sling?
11--2
air