Figure 3-1 3/8 Inch Carriage Bolts Thru Floor; Figure 3-2 Condenser Mounted With Hardware - Carrier Transport Air Conditioning Installation Procedures Manual

Transport air conditioning, split systems generation 4 & 5
Table of Contents

Advertisement

The condenser assembly should contact as
many of the floor supports (stringers) as pos-
sible, while hitting the least amount of skirt sup-
ports.
Always attempt to use at least one of the ve-
hicles floor supports (stringers) to mount the
condenser assembly.
j. Drill pilot holes up through the bus (vehicle) floor.
CAUTION
Make sure there is nothing installed where
you are going to drill through the bus floor.
k. Using the pilot holes, drill 7/16 inch holes through the
bus floor or stringers. See Figure 3-1.
NOTE
To safely attach/mount the CM-2 it will require a
minimum of 4 bolts, while the CM-3 requires 6
bolts.
NOTE
Block spacers or jam-nuts may be required if
the condenser mounting area is not tight
against the bus stringers. See Figure 3-3.
Note
Note

Figure 3-1 3/8 Inch Carriage Bolts Thru Floor

l. Mount the condenser using 3/8 inch diameter hard-
ware. See Figure 3-2.
m.Install grill/screen on condenser assembly or skirt of
bus, depending on application.
n. Connect discharge and liquid lines. Refer to Section
4, hose routing.
o. Connect electrical harness to condenser. Refer to
Section 5, electrical.

Figure 3-2 Condenser Mounted With Hardware

3--3
Bus Floor
Bus Stringer
T--311