Carrier 24ABR3 Product Data

Carrier 24ABR3 Product Data

Base series 13 air conditioner sizes 18 to 60 1-1/2 to 5 nominal tons

Advertisement

24ABR3
BasetSeries 13 Air Conditioner
Sizes 18 to 60
1---1/2 to 5 Nominal Tons

Product Data

INDUSTRY LEADING
FEATURES / BENEFITS
Efficiency
Sound
Comfort
Reliability
Durability
WeatherArmort protection package:
A05341
Applications
Warranty
Single Phase
Three Phase
S
13 SEER/11 EER (Nominal)
S
Microtube Technologyt refrigeration system
S
Indoor air quality accessories available
Sound level as low as 76 dBA
S
S
As low as 73 dBA with optional accessory sound hood
S
System supports Thermidistatt or standard thermostat
controls
S
Front- -seating service valves
S
Scroll compressor
Internal pressure relief valve
S
S
Internal thermal overload
S
Filter drier
S
Balanced refrigeration system for maximum reliability
S
Solid, Durable sheet metal construction
S
Wire coil guard
S
Baked- -on, complete coverage, powder paint
S
Long- -line - - up to 250 feet total equivalent length, up
to 200 feet condenser above evaporator, or up to 80 ft.
evaporator above condenser (See Longline Guide for
more information.)
S
Low ambient (down to - -20_F) with accessory kit
5 year limited compressor warranty
S
S
5 year limited parts warranty
S
5 year limited compressor warranty
S
1 year limited parts warranty

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 24ABR3 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Carrier 24ABR3

  • Page 1: Product Data

    24ABR3 BasetSeries 13 Air Conditioner Sizes 18 to 60 1---1/2 to 5 Nominal Tons Product Data INDUSTRY LEADING FEATURES / BENEFITS Efficiency 13 SEER/11 EER (Nominal) Microtube Technologyt refrigeration system Indoor air quality accessories available Sound Sound level as low as 76 dBA...
  • Page 2: Model Number Nomenclature

    Defined 6=460/3 Coil Guard Series ISO 9001:2000 REGISTERED As an Energy Star® Partner, Carrier Corporation has determined that this product meets the ENERGY STAR® guidelines for energy efficiency. Refer to the combination ratings in Product Data for system combinations that meet Energy Star guidelines.
  • Page 3: Physical Data

    PHYSICAL DATA UNIT SIZE SERIES 18--- 30 24--- 31 30--- 31 36--- 31 42--- 30 48--- 31 60--- 32/33 Operating Weight (lb) Shipping Weight (lb) Compressor Type Scroll REFRIGERANT Freon® (R--- 22) Control TXV (R--- 22 Hard Shutoff) Charge (lb) 4.90 4.88 5.25...
  • Page 4 ACCESSORY THERMOSTATS DESCRIPTION THERMOSTAT / SUBBASE PKG. TSTATCCPRH01--- B Thermidistat Control --- Programmable / Non--- Programmable Thermostat with Humidity control TSTATCCPAC01--- B Thermostat --- Auto Changeover, 7--- Day Programmable, _F/_C, 1--- Stage Heat, 1--- Stage Cool TSTATCCNAC01--- C Thermostat --- Auto Changeover, Non--- Programmable, _F/_C, 1--- Stage Heat, 1--- Stage Cool TSTATCCBAC01--- B Builder’s Thermostat --- Manual Changeover, Non--- Programmable, _F/_C, 1--- Stage Heat, 1--- Stage Cool TSTATCCSEN01--- B...
  • Page 5 Required in Longline applications. 9. Outdoor Air Temperature Sensor Suggested in all commercial applications. Designed for use with Carrier Thermostats listed in this publication. This device enables the thermostat to display the outdoor temperature. This device also is required to enable special thermostat features such as auxiliary heat lock out.
  • Page 6 Accessory Description and Usage (Listed Alphabetically) (Continued) 10. Sound Hood 13. Time- -Delay Relay Wraparound sound reducing cover for the compressor. Reduces An SPST delay relay which briefly continues operation of indoor the sound level by about 2 dBA. blower motor to provide additional cooling after the compressor cycles off.
  • Page 7: Electrical Data

    ELECTRICAL DATA MIN WIRE UNIT SIZE--- MAX FUSE** LENGTH LENGTH OPER VOLTS* COMPR MIN WIRE SIZE VOLTAGE, SIZE V/PH (FT) (FT) SERIES CKT BRK AMPS 60° C 75° C 60° C 75° C 18--- 30 40.3 10.1 24--- 31 54.0 10.4 0.75 13.8...
  • Page 9 COMBINATION RATINGS SEER Unit Size --- Factory Indoor Total Cap. Furnace Voltage, Supplied Standard Model BTUH Model TDR{ Series Enhancement Rating *CAR**1814A** 17,300 13.00 11.00 CAR**1814A** 17,000 TDR&TXV 14.00 11.50 58CV(A,X)070---12 CAR**2414A** 17,700 13.00 11.00 CAR**2414A** 17,400 TDR&TXV 14.00 11.50 58CV(A,X)070---12 CAR**2417A** 17,700...
  • Page 10: Combination Ratings Continued

    COMBINATION RATINGS CONTINUED SEER Unit Size --- Factory Indoor Total Cap. Furnace Voltage, Supplied Standard Model BTUH TDR{ Model Series Enhancement Rating CNRV*3017A** 23,000 TDR&TXV 14.00 11.50 58MVB060---14 CNRV*3017A** 23,000 TDR&TXV 14.00 11.50 58CV(A,X)090---16 CNRH*2417A** 23,200 13.00 11.00 CNRH*2417A** 23,000 TDR&TXV 14.00 11.50...
  • Page 11 COMBINATION RATINGS CONTINUED SEER Unit Size --- Factory Indoor Total Cap. Furnace Voltage, Supplied Standard Model BTUH TDR{ Model Series Enhancement Rating *CAR**3014A** 28,000 13.00 11.00 CAR**3014A** 27,800 TDR&TXV 14.00 11.50 58CV(A,X)070---12 CAR**3017A** 28,000 13.00 11.00 CAR**3017A** 27,800 TDR&TXV 14.00 11.50 58MVB060---14 CAR**3017A**...
  • Page 12 COMBINATION RATINGS CONTINUED SEER Unit Size --- Factory Indoor Total Cap. Furnace Voltage, Supplied Standard Model BTUH TDR{ Model Series Enhancement Rating CSRH*3012A** 27,800 TDR&TXV 14.00 11.50 58MVB120---20 CSRH*3012A** 27,800 TDR&TXV 14.00 11.50 58CV(A,X)070---12 CSRH*3012A** 27,800 TDR&TXV 14.00 11.50 58CV(A,X)090---16 CSRH*3012A** 27,800 TDR&TXV...
  • Page 13 COMBINATION RATINGS CONTINUED SEER Unit Size --- Factory Indoor Total Cap. Furnace Voltage, Supplied Standard Model BTUH TDR{ Model Series Enhancement Rating CNRH*3617A** 34,000 13.00 11.00 CNRH*3617A** 33,800 TDR&TXV 13.50 11.20 58MVB040---14 CNRH*3617A** 33,800 TDR&TXV 13.50 11.20 58MVB060---14 CNRH*3617A** 33,800 TDR&TXV 13.50 11.20...
  • Page 14 COMBINATION RATINGS CONTINUED SEER Unit Size --- Factory Indoor Total Cap. Furnace Voltage, Supplied Standard Model BTUH TDR{ Model Series Enhancement Rating *CAR**4221A** 40,500 13.00 11.00 CAR**4221A** 40,000 TDR&TXV 13.50 11.20 58MVB080---14 CAR**4221A** 40,000 TDR&TXV 13.50 11.20 58MVB080---20 CAR**4221A** 40,000 TDR&TXV 13.50 11.20...
  • Page 15 COMBINATION RATINGS CONTINUED SEER Unit Size --- Factory Indoor Total Cap. Furnace Voltage, Supplied Standard Model BTUH TDR{ Model Series Enhancement Rating CNRF*4818A** 40,500 13.00 11.00 CSRH*4212A** 40,500 13.00 11.00 CSRH*4212A** 40,000 TDR&TXV 13.50 11.20 58MVB040---14 CSRH*4212A** 40,000 TDR&TXV 13.50 11.20 58MVB060---14 CSRH*4212A**...
  • Page 16 COMBINATION RATINGS CONTINUED SEER Unit Size --- Factory Indoor Total Cap. Furnace Voltage, Supplied Standard Model BTUH TDR{ Model Series Enhancement Rating CNRV*6024A** 46,500 TDR&TXV 13.50 11.20 58MVB120---20 CNRV*6024A** 46,500 TDR&TXV 13.50 11.20 58CV(A,X)135---22 CNRV*6024A** 47,000 TDR&TXV 14.00 11.50 58CV(A,X)155---22 48---31 48---51 CNRH*4821A**...
  • Page 17 { In most cases, only 1 method should be used to achieve TDR function. Using more than 1 method in a system may cause degradation in performance. Use either the accessory Time---Delay Relay KAATD0101TDR or a furnace equipped with TDR. Most Carrier furnaces are equipped with TDR.
  • Page 18 DETAILED COOLING CAPACITIES CONDENSER ENTERING AIR TEMPERATURES deg F EVAPORATOR Capacity Capacity Capacity Capacity Capacity Capacity Total Sys- Total Total Total Total Total MBtuh{ MBtuh{ System MBtuh{ System MBtuh{ System MBtuh{ System MBtuh{ System KW** KW** KW** KW** KW** KW** Total Sens} Total...
  • Page 19 DETAILED COOLING CAPACITIES CONDENSER ENTERING AIR TEMPERATURES deg F EVAPORA- TOR AIR Capacity Capacity Capacity Capacity Capacity Capacity MBtuh{ MBtuh{ MBtuh{ MBtuh{ MBtuh{ MBtuh{ Total Sys- Total Sys- Total Sys- Total Sys- Total Sys- Total Sys- tem KW** tem KW** tem KW** tem KW** tem KW**...
  • Page 20 DETAILED COOLING CAPACITIES CONDENSER ENTERING AIR TEMPERATURES deg F EVAPORA- TOR AIR Capacity Capacity Capacity Capacity Capacity Capacity MBtuh{ MBtuh{ MBtuh{ MBtuh{ MBtuh{ MBtuh{ Total Sys- Total Sys- Total Sys- Total Sys- Total Sys- Total Sys- tem KW** tem KW** tem KW** tem KW** tem KW**...
  • Page 21 DETAILED COOLING CAPACITIES CONDENSER ENTERING AIR TEMPERATURES deg F EVAPORA- TOR AIR Capacity Capacity Capacity Capacity Capacity Capacity MBtuh{ MBtuh{ MBtuh{ MBtuh{ MBtuh{ MBtuh{ Total Sys- Total Sys- Total Sys- Total Sys- Total Sys- Total Sys- tem KW** tem KW** tem KW** tem KW** tem KW**...
  • Page 22 DETAILED COOLING CAPACITIES CONDENSER ENTERING AIR TEMPERATURES deg F EVAPORA- TOR AIR Capacity Capacity Capacity Capacity Capacity Capacity MBtuh{ MBtuh{ MBtuh{ MBtuh{ MBtuh{ MBtuh{ Total Sys- Total Sys- Total Sys- Total Sys- Total Sys- Total System tem KW** tem KW** tem KW** tem KW** tem KW**...
  • Page 23 DETAILED COOLING CAPACITIES CONDENSER ENTERING AIR TEMPERATURES deg F EVAPORA- TOR AIR Capacity Capacity Capacity Capacity Capacity Capacity MBtuh{ MBtuh{ MBtuh{ MBtuh{ MBtuh{ MBtuh{ Total Sys- Total Sys- Total Sys- Total Sys- Total Sys- Total Sys- tem KW** tem KW** tem KW** tem KW** tem KW**...
  • Page 24 DETAILED COOLING CAPACITIES CONDENSER ENTERING AIR TEMPERATURES deg F EVAPORA- TOR AIR Capacity Capacity Capacity Capacity Capacity Capacity MBtuh{ MBtuh{ MBtuh{ MBtuh{ MBtuh{ MBtuh{ Total Sys- Total Sys- Total Sys- Total Sys- Total Sys- Total Sys- tem KW** tem KW** tem KW** tem KW** tem KW**...
  • Page 25 GUIDE SPECIFICATIONS AIR- -COOLED, SPLIT- -SYSTEM AIR CONDITIONER 24ABR3 GENERAL 1- -1/2 TO 5 NOMINAL TONS System Description Fans — Condenser fan will be direct- -drive propeller type, Outdoor- -mounted, air- -cooled, split- -system air conditioner discharging air upward. unit suitable for ground or rooftop installation. Unit consists of a hermetic compressor, an air- -cooled coil, propeller- -type —...
  • Page 26 Copyright 2006 Carrier Corp. S 7310 W. Morris St. S Indianapolis, IN 46231 Printed in U.S.A. edition date: 03 / 06 Catalog No: 24ABR3---2PD Replaces:24ABR3---1PD Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.

Table of Contents

Save PDF