Carrier 24ABA4 Product Data

Carrier 24ABA4 Product Data

Base series 14 air conditioner with puronr refrigerant

Advertisement

24ABA4
BasetSeries 14 Air Conditioner
with Puronr Refrigerant
the environmentally sound refrigerant
Carrier's Air Conditioners with Puronr refrigerant provide a
collection of features unmatched by any other family of
equipment. The 24ABA has been designed utilizing Carrier's
Puron refrigerant. The environmentally sound refrigerant allows
you to make a responsible decision in the protection of the earth's
ozone layer. Carrier's air conditioning system with Puron
refrigerant meets the Energy Star r guidelines for energy
efficiency.

Product Data

INDUSTRY LEADING
FEATURES / BENEFITS
Efficiency
S
S
S
Sound
S
Comfort
S
Reliability
S
S
S
S
S
A04030
S
S
Durability
WeatherArmort protection package:
S
S
S
Applications
S
S
Warranty
S
S
14 SEER/11 EER
Microtube Technologyt refrigeration system
Indoor air quality accessories available
Sound level as low as 76 dBA
System supports Thermidistatt or standard thermostat
controls
Puronr refrigerant - - environmentally sound, won't
deplete the ozone layer and low lifetime servce cost.
Front- -seating service valves
Scroll compressor
Internal pressure relief valve
Internal thermal overload
Filter drier
Balanced refrigeration system for maximum reliability
Solid, Durable sheet metal construction
Dense wire coil guard
Baked- -on, complete coverage, powder paint
Long- -line - - up to 250 feet total equivalent length, up
to 200 feet condenser above evaporator, or up to 80 ft.
evaporator above condenser (See Longline Guide for
more information.)
Low ambient (down to - -20_F) with accessory kit
5 year limited compressor warranty
5 year limited parts warranty

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 24ABA4 and is the answer not in the manual?

Questions and answers

Summary of Contents for Carrier 24ABA4

  • Page 1: Product Data

    Filter drier the environmentally sound refrigerant Balanced refrigeration system for maximum reliability Durability Carrier’s Air Conditioners with Puronr refrigerant provide a collection of features unmatched by any other family of WeatherArmort protection package: equipment. The 24ABA has been designed utilizing Carrier’s Solid, Durable sheet metal construction Puron refrigerant.
  • Page 2: Model Number Nomenclature

    MODEL NUMBER NOMENCLATURE Product Product Major Cooling Tier SEER Variations Open Open Voltage Series Series Family Series Capacity 0=Not 0=Not 3=208/230 ---1 24=AC A=RES AC B=Base A=Puron 4=14 SEER A=Standard Original Defined Defined Series ISO 9001:2000 the environmentally sound refrigerant REGISTERED STANDARD FEATURES Feature...
  • Page 3: Physical Data

    PHYSICAL DATA UNIT SIZE SERIES 18 ---30 24 ---30 30 ---30 36 ---30 42 ---30 48 ---30 60 ---30 Operating Weight (lb) Shipping Weight (lb) Compressor Type Scroll REFRIGERANT Puron® (R--- 410A) Control TXV (Puron® Hard Shutoff) Charge (lb) 7.25 7.25 10.9 13.9...
  • Page 4: Accessory Thermostats

    ACCESSORY THERMOSTATS THERMOSTAT / SUBBASE PKG. DESCRIPTION TSTATCCPRH01--- B Thermidistat Control --- Programmable / Non--- Programmable Thermostat with Humidity control TSTATCCPAC01--- B Thermostat --- Auto Changeover, 7--- Day Programmable, _F/_C, 1--- Stage Heat, 1--- Stage Cool TSTATCCNAC01--- C Thermostat --- Auto Changeover, Non--- Programmable, _F/_C, 1--- Stage Heat, 1--- Stage Cool TSTATCCBAC01--- B Builder’s Thermostat --- Manual Changeover, Non--- Programmable, _F/_C, 1--- Stage Heat, 1--- Stage Cool TSTATCCSEN01--- B...
  • Page 5 Low ambient cooling 9. Outdoor Air Temperature Sensor Hard shut off expansion valve on indoor coil Designed for use with Carrier Thermostats listed in this publication. This device enables the thermostat to display the Liquid line solenoid on indoor coil outdoor temperature.
  • Page 6: Electrical Data

    Accessory Description and Usage (Listed Alphabetically) - - Continued 13. Time- -Delay Relay For improved efficiency ratings for certain combinations of indoor and outdoor units. Refer to An SPST delay relay which briefly continues operation of indoor ARI Unitary Directory. blower motor to provide additional cooling after the compressor 14.
  • Page 8: Combination Ratings

    COMBINATION RATINGS SEER Unit Size Factory Supplied Indoor Model Total Cap. BTUH Furnace Model Standard --- Series Enhancement TDR† Rating *CAP**2414A** 18,000 14.00 11.5 CAP**1814A** 17,600 TDR&TXV 15.00 12.50 58CV(A,X)070---12 CAP**1814A** 17,800 13.50 11.20 CAP**2414A** 17,900 TDR&TXV 15.00 13.00 58CV(A,X)070---12 CAP**2417A** 17,900 TDR&TXV...
  • Page 9 COMBINATION RATINGS - - CONTINUED SEER Unit Size --- Factory Supplied Indoor Model Total Cap. BTUH Furnace Model Standard Series Enhancement TDR† Rating CNPH*2417A** 23,600 14.00 11.50 CNPH*2417A** 23,400 TDR&TXV 15.00 12.50 58MVB040---14 CNPH*2417A** 23,400 TDR&TXV 15.00 12.50 58CV(A,X)070---12 24 ---30 CNPH*3017A** 24,000 14.00...
  • Page 10 COMBINATION RATINGS - - CONTINUED SEER Unit Size --- Factory Supplied Indoor Model Total Cap. BTUH Furnace Model Standard Series Enhancement TDR† Rating CNPH*3017A** 29,000 14.00 11.50 CNPH*3017A** 28,800 TDR&TXV 15.00 12.50 58MVB040---14 CNPH*3017A** 28,800 TDR&TXV 15.00 12.50 58MVB120---20 CNPH*3017A** 28,800 TDR&TXV 15.00...
  • Page 11 COMBINATION RATINGS - - CONTINUED SEER Unit Size --- Factory Supplied Indoor Model Total Cap. BTUH Furnace Model Standard Series Enhancement TDR† Rating CNPH*4221A** 35,600 TDR&TXV 15.00 13.00 58CV(A,X)155---22 CNPF*3618A** 35,400 14.00 11.50 CSPH*3612A** 36,200 14.00 11.50 CSPH*3612A** 35,600 TDR&TXV 15.00 12.00 58MVB040---14...
  • Page 12 COMBINATION RATINGS - - CONTINUED SEER Unit Size --- Factory Supplied Indoor Model Total Cap. BTUH Standard Furnace Model Series Enhancement TDR† Rating CSPH*4812A** 40,000 TDR&TXV 15.00 13.20 58MVB040---14 CSPH*4812A** 40,000 TDR&TXV 14.50 12.00 58CV(A,X)070---12 FY4ANF042 40,000 TDR&TXV 13.50 11.20 FY4ANF048 41,000 TDR&TXV...
  • Page 13 { In most cases, only 1 method should be used to achieve TDR function. Using more than 1 method in a system may cause degradation in performance. Use either the accessory Time---Delay Relay KAATD0101TDR or a furnace equipped with TDR. Most Carrier furnaces are equipped with TDR.
  • Page 14: Detailed Cooling Capacities

    DETAILED COOLING CAPACITIES CONDENSER ENTERING AIR TEMPERATURES deg F EVAPORATOR Capacity Capacity Capacity Capacity Capacity Capacity Total Total Total Total Total Total MBtuh† MBtuh† MBtuh† MBtuh† MBtuh† MBtuh† System System System System System System Sens Sens Sens Sens Sens Sens KW** KW** KW**...
  • Page 15 DETAILED COOLING CAPACITIES CONDENSER ENTERING AIR TEMPERATURES deg F EVAPORATOR Capacity Capacity Capacity Capacity Capacity Capacity Total Total Total Total Total Total MBtuh† MBtuh† MBtuh† MBtuh† MBtuh† MBtuh† System System System System System System Sens Sens Sens Sens Sens Sens KW** KW** KW**...
  • Page 16 DETAILED COOLING CAPACITIES CONDENSER ENTERING AIR TEMPERATURES deg F EVAPORATOR Capacity Capacity Capacity Capacity Capacity Capacity Total Total Total Total Total Total MBtuh† MBtuh† MBtuh† MBtuh† MBtuh† MBtuh† System System System System System System Sens Sens Sens Sens Sens Sens KW** KW** KW**...
  • Page 17 DETAILED COOLING CAPACITIES CONDENSER ENTERING AIR TEMPERATURES deg F EVAPORATOR Total Total Total Total Total Total Capacity Capacity Capacity Capacity Capacity Capacity Sys- Sys- Sys- Sys- Sys- Sys- MBtuh† MBtuh† MBtuh† MBtuh† MBtuh† MBtuh† Total Sens‡ Total Sens‡ Total Sens‡ Total Sens‡...
  • Page 18 DETAILED COOLING CAPACITIES CONDENSER ENTERING AIR TEMPERATURES deg F EVAPORATOR Capacity Capacity Capacity Capacity Capacity Capacity Total Total Total Total Total Total MBtuh† MBtuh† MBtuh† MBtuh† MBtuh† MBtuh† System System System System System System Sens Sens Sens Sens Sens Sens KW** KW** KW**...
  • Page 19 DETAILED COOLING CAPACITIES CONDENSER ENTERING AIR TEMPERATURES deg F EVAPORATOR Total Total Total Total Total Total Capacity Capacity Capacity Capacity Capacity Capacity Sys- Sys- Sys- Sys- Sys- Sys- MBtuh† MBtuh† MBtuh† MBtuh† MBtuh† MBtuh† Total Sens‡ Total Sens‡ Total Sens‡ Total Sens‡...
  • Page 20 DETAILED COOLING CAPACITIES CONDENSER ENTERING AIR TEMPERATURES deg F EVAPORATOR Capacity Capacity Capacity Capacity Capacity Capacity Total Total Total Total Total Total MBtuh† MBtuh† MBtuh† MBtuh† MBtuh† MBtuh† System System System System System System KW** KW** KW** KW** KW** KW** Total Sens‡...
  • Page 21 GUIDE SPECIFICATIONS AIR- -COOLED, SPLIT- -SYSTEM AIR CONDITIONER 24ABA4 GENERAL 1- -1/2 TO 5 NOMINAL TONS System Description — Condenser fan motors will be totally enclosed, 1- -phase type with class B insulation and permanently Outdoor- -mounted, air- -cooled, split- -system air conditioner lubricated bearings.
  • Page 22 Copyright 2005 Carrier Corp. S 7310 W. Morris St. S Indianapolis, IN 46231 Printed in U.S.A. edition date: 12 / 05 Catalog No: 24ABA4---1PD Replaces:New Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.

Table of Contents

Save PDF