Figure 3-7 Mounting Options; Figure 3-8 Kr4 Condenser Mounted Without Mounting Channels (Front/Back View); Figure 3-9 Kr4 Condenser Mounted With Mounting Channels (Front/Back View); Figure 3-10 Kr4 Condenser Mounted Without Mounting Channels (Side View) - Carrier Transport Air Conditioning Installation Procedures Manual

Transport air conditioning, split systems generation 4 & 5
Table of Contents

Advertisement

1/4 In. steel
monobolt.
Without Mounting Channel

Figure 3-8 KR4 Condenser Mounted Without Mounting Channels (Front/Back View)

Figure 3-9 KR4 Condenser Mounted With Mounting Channels (Front/Back View)

Roof Bow
Bus Roof

Figure 3-10 KR4 Condenser Mounted Without Mounting Channels (Side View)

Sealant
Bus roof outer skin
Roof bow

Figure 3-7 Mounting Options

Roof Bow
Center of condenser assembly must contact bus roof
Roof Bow
Center of condenser assembly must contact bus roof
Apply sealant to unit mounting surface
and rivet heads to prevent water leaks
3--7
Bolt, 3/8-16 X 1-1/4 In.
4 per side.
3/8 In. flat washer
3/8 In. flat washer
Mounting channel
Bus roof outer skin
Roof bow
With Mounting Channel
Roof Bow
Mounting
Channel
Bus Roof
T--311