Chapter 4 - Jumper Settings; Power-On/ Clear Cmos - DFI EC800 User Manual

Fanless embedded system
Hide thumbs Also See for EC800:
Table of Contents

Advertisement

Chapter 4 - Jumper Settings

Power-on/ Clear CMOS

Power-on
JP5 is used to select the method of powering on the system. If you want the system to pow-
er-on whenever AC power comes in, set JP5 pins 3 and 5 to On. If you want to use the power
button, set pins 1 and 3 to On.
When using the JP5 "Power On" feature to power the system back on after a power failure
occurs, the system may not power on if the power lost is resumed within 5 seconds (power
flicker).
Note:
In order to ensure that power is resumed after a power failure that re covers within a
5 second period, JP5 must be set to pins 3-5 and the "AC Power Lose" in CMOS is set
to "On".
Chapter 4 Jumper Settings
Chapter 4
1
2
JP5
3
4
5
6
1-3 On: Power-on via
power button (default)
1
2
3
4
5
6
3-5 On: Auto Power-on
15
1
2
3
4
5
6
2-4 On: Normal
(default)
1
2
3
4
5
6
4-6 On: Clear CMOS
Clear CMOS
If you encounter the following,
a) CMOS data becomes corrupted.
b) You forgot the supervisor or user password.
you can reconfigure the system with the default values stored in the ROM BIOS.
To load the default values stored in the ROM BIOS, please follow the steps below.
1. Power-off the system and unplug the power cord.
2. Set JP5 pins 4 and 6 to On. Wait for a few seconds and set JP5 back to its default setting,
pins 2 and 4 On.
3. Now plug the power cord and power-on the system.
www.dfi .com