Appendix A - Watchdog Sample Code - DFI EC800 User Manual

Fanless embedded system
Hide thumbs Also See for EC800:
Table of Contents

Advertisement

Appendix A - Watchdog Sample Code

;Software programming example:
;---------------------------------------------
;(1) Enter Super IO Confi guration mode
;---------------------------------------------
MOV
DX,2EH
MOV
AL,87H
OUT
DX,AL
OUT
DX,AL
;-------------------------------------------------------------------------------------------
;(2) Confi guration Logical Device 7, register CRF5/CRF6 (WDT Control /WDT
timer)
;-------------------------------------------------------------------------------------------
MOV
DX,2EH
MOV
AL,07H
;Ready to Program Logical Device
OUT
DX,AL
MOV
DX,2FH
MOV
AL,07H
;Select Logical Device 7
OUT
DX,AL
MOV
DX,2EH
MOV
AL, F6H
;Select watchdog timer register
OUT
DX,AL
MOV
DX,2FH
MOV
AL,10H
;Set watchdog timer value
OUT
DX,AL
MOV
DX,2EH
MOV
AL, F5H
;Select watchdog Control Register
OUT
DX,AL
MOV
DX,2FH
MOV
AL,61H
;Set Watchdog Control Value
OUT
DX,AL
;----------------------------------------------------------------
;(1) Exit extended function mode
;----------------------------------------------------------------
MOV
DX,2EH
MOV
AL,AAH
OUT
DX,AL
Appendix A Watchdog Sample Code