Serial Port 1 Configuration to Serial Port 2 Configuration
Aptio Setup Utility - Copyright (C) 2012 American Megatrends, Inc.
Advanced
Serial Port 1 Confi guration
Serial Port
[Enabled]
IO=3F8h; IRQ=4;
Device Settings
Change Settings
[Auto]
COM1 Driver Mode
[RS232 driver]
Version 2.14.1219. Copyright (C) 2012 American Megatrends, Inc.
Aptio Setup Utility - Copyright (C) 2012 American Megatrends, Inc.
Advanced
Serial Port 2 Confi guration
Serial Port
[Enabled]
Device Settings
IO=2F8h; IRQ=3;
Change Settings
[Auto]
COM2 Driver Mode
[RS232 driver]
Version 2.14.1219. Copyright (C) 2012 American Megatrends, Inc.
Serial Port
Enables or disables the serial port.
Change Settings
Selects the IO/IRQ setting of the I/O device.
COM1/2 Driver Mode
Enable or disable serial port (COM)
Chapter 7 BIOS Setup
Chapter 7
Enable or Disable Serial
Port (COM)

Select Screen

Select Item
Enter: Select
+/ -:
Change Opt.
F1:
General Help
F2:
Previous Values
F3:
Optimized Defaults
F4:
Save & Exit
ESC: Exit
Enable or Disable Serial
Port (COM)

Select Screen

Select Item
Enter: Select
+/ -:
Change Opt.
F1:
General Help
F2:
Previous Values
F3:
Optimized Defaults
F4:
Save & Exit
ESC: Exit
37
PC Health Status
This section displays the hardware health monitor.
Aptio Setup Utility - Copyright (C) 2012 American Megatrends, Inc.
Advanced
PC Health Status
Smart Fan Function
[Enabled]
Smart Fan Mode Confi guration
CPU Temperature
: +34 C
System Temperature
: +35 C
System FAN Speed
: N/A
VCore
: +1.064 V
VCCGFX
: +1.048 V
V_SM
: +1.568 V
1.05V
: +1.064 V
5VSB
: +4.992 V
3VCC
: +3.344 V
3VSB
: +3.360 V
VBAT
: +3.312 V
Version 2.14.1219. Copyright (C) 2012 American Megatrends, Inc.
Smart Fan Mode Configuration
Aptio Setup Utility - Copyright (C) 2012 American Megatrends, Inc.
Advanced
Smart Fan Mode Confi guration
System Fan Smart Fan
[Auto Duty-Cycle Mode]
Temperature 1
60
Temperature 2
50
Temperature 3
40
Temperature 4
30
Duty Cycle 1
85
Duty Cycle 2
70
Duty Cycle 3
60
Duty Cycle 4
50
Version 2.14.1219. Copyright (C) 2012 American Megatrends, Inc.
Enable or Disable Smart
Fan

Select Screen

Select Item
Enter: Select
+/ -:
Change Opt.
F1:
General Help
F2:
Previous Values
F3:
Optimized Defaults
F4:
Save & Exit
ESC: Exit
Smart Fan Mode Select

Select Screen

Select Item
Enter: Select
+/ -:
Change Opt.
F1:
General Help
F2:
Previous Values
F3:
Optimized Defaults
F4:
Save & Exit
ESC: Exit
www.dfi .com

Advertisement

Table of Contents
loading

Table of Contents