CAUTION
To insure adequate bonding when attaching the provided Panduit LCD6-10AF two-hole ground
lug, a minimum of 20 PSI of torque is required to be applied to the mounting hardware used to
attach the ground lug. Use a star washer to ensure an NEBS compliant connection.

Verifying proper operation

To verify the proper operation of the power supply after power on, you can observe the LEDs on the
power supply.
After the Brocade device powers on, you can observe the LEDs on the front of the device to verify
that it initialized successfully. There is a single LED on the power supply which should be steady
green when the power supply is receiving power and under normal operation.Table 1 outlines the
LEDs, the desired state of each LED, possible abnormal states of each LED, and what to do if an
LED indicates an abnormal state.
To verify proper operation, complete the following steps.
1. Verify that the power supply's LED is steady green on the back of the device.
2. Verify that the power supply was placed in power supply bay #1 and operational by observing a
TABLE 13
LED
Fan (labeled Fn)
PS1 (labeled P1)
PS2 (labeled P2)
Brocade NetIron CES and Brocade NetIron CER Hardware Guide
53-0000080-03
steady green LED lighting up "P1" on the front of the device.
LEDs for power and fans (located on front of device )
State
On
Off
Off
Amber
Green Steady
Green Blinking
Off
Amber
Green Steady
Green Blinking
Power supply replacement
Meaning
The fan tray is powered on and is operating
normal.
The fan tray is not powered on, or has been
removed.
Power supply 1 is not installed or is not
providing power.
Power supply 1 is installed, but not connected
or a fault is detected.
Power supply 1 is installed and is functioning
normally.
Power supply 1 has input power, but is not
enabled and has no output power.
Power supply 2 is not installed or is not
providing power.
Power supply 2 is installed, but not connected
or a fault is detected.
Power supply 2 is installed and is functioning
normally.
Power supply 2 has input power, but is not
enabled and has no output power.