Power supply replacement
FIGURE 40
CAUTION
Make sure you insert the power supply right-side up. It is possible to insert the supply upside
down, although the supply will not engage with the power backplane when upside down. The
power supply is right-side up when the manufacturer label is on the top.
4. Tighten the two power supply locking screws located at the top left and bottom right hand
5. Connect the power cord to the power supply.
Removing the DC power supply
Required tools
You will need the following tool to perform this procedure:
The following procedures are required when removing an DC power supplies from devices.
1. Remove the wires from your DC power source.
2. Unscrew the two assembly screws to unlock the DC wiring assembly
3. Loosen the wire tightening screws to remove the wires
62
Power supply installation
corner of the power supply.
#2 Phillips-head screwdriver
the adapter.
assembly.
(Figure
42) from the DC wiring
Brocade NetIron CES and Brocade NetIron CER Hardware Guide
(Figure
41) and remove
53-0000080-03