5
Power supply replacement
5. Pull the power supply outward once the screws have been unscrewed. This will disconnect the
6. Place the power supply in an anti-static bag for storage.
7.
Installing a DC power supply
DANGER
Before beginning the installation, refer to the precautions in
Use the following procedures for DC power supplies in Brocade devices.
Follow the steps given below to install an DC power supply.
1. If necessary, remove the power supply locking screws located in the upper left and the bottom
2. If the empty power supply bay has a cover plate, remove the two screws near the edges of the
3. Remove the DC power supply from its packaging
FIGURE 43
4. Insert the wires into the DC wiring assembly
5. Use the wire tightening screws to secure the wires.
6. Insert the DC connector with wires to the power supply and tighten the two assembly screws.
64
power supply from the backplane. Pull it completely free of the chassis.
Insert a new supply, or place and screw in a cover plate over the empty power supply. Refer to
"Installing a DC power supply"
right of the device.
cover plate to unlock the plate, then remove the plate.
The DC power supply
on page 64 for details.
(Figure
(Figure
44).
Brocade NetIron CES and Brocade NetIron CER Hardware Guide
"Power precautions"
on page 30.