Table 3-2
POST Error Messages
continued
Error Code
Audible Beeps
1796-Drive Array –
None
Array Accelerator
Not Responding.
Array Accelerator is
temporarily
disabled.
1797-Drive Array –
None
Array Accelerator
Read Error
Occurred.
Data in Array
Accelerator has
been lost.
Array Accelerator is
disabled.
1798-Drive Array –
None
Array Accelerator
Write Error
Occurred.
Array Accelerator is
disabled.
1799-Drive Array –
None
Drive(s) Disabled
due to Array
Accelerator Data
Loss.
Select "F1" to
continue with
logical drives
disabled.
Select "F2" to
accept data loss
and to re-enable
logical drives.
Probable Source of
Action
Problem
Array accelerator is
1.
defective or has been
removed.
2.
Hard parity error
Enable array accelerator.
detected while
reading data from
posted-writes
memory.
Hard parity error
Enable array accelerator.
detected while writing
data to posted-writes
memory.
Volume failed due to
Press F1 to continue with logical drives
loss of data in
disabled or F2 to accept data loss and
posted-writes
re-enable logical drives.
memory.
Diagnostics and Troubleshooting 3-37
Check that the array accelerator is
properly seated.
Run the server setup utility to
reconfigure the Compaq IDA-2
without the array accelerator.
continued