3-24 Compaq ProLiant ML350 Maintenance and Service Guide
Table 3-2
POST Error Messages
Error Code
1729-Slot 1 Drive
Array – Disk
Consistency
Initialization in
Progress –
RAID 4/5
performance may
be lower until Auto
Reliability
Monitoring has
completed
Automatic
Background Parity
Consistency
Initialization.
1730-Fixed Disk 0
does not support
DMA Mode.
1731-Fixed Disk 1
does not support
DMA Mode.
1740-Fixed Disk 0
failed Set Block
Mode command
1741-Fixed Disk 1
failed Set Block
Mode command
1750-Fixed Disk 0
failed Identify
command
1751-Fixed Disk 1
failed Identify
command
continued
Audible Beeps
Probable Source of
Problem
None
Initial RAID
configuration in
progress.
None
Hard drive error
detected.
None
Hard drive error
detected.
None
Hard drive error
detected.
None
Hard drive error
detected.
None
Hard drive error
detected.
None
Hard drive error
detected.
Action
This message is normal following the
initial configuration of RAID 4 or RAID 5
logical drives. Performance of the
controller improves after the parity data
has been initialized by ARM (an
automatic process that runs in the
background on the controller).
Run the server setup utility and correct.
Run the server setup utility and correct.
Run the server setup utility and correct.
Run the server setup utility and correct.
Run the server setup utility and correct.
Run the server setup utility and correct.
continued

Advertisement

Table of Contents
loading