Compaq ProLiant ML350 Maintenance And Service Manual page 65

Proliant ml350
Hide thumbs Also See for ProLiant ML350:
Table of Contents

Advertisement

3-10 Compaq ProLiant ML350 Maintenance and Service Guide
Table 3-2
POST Error Messages
Error Code
174-
Configuration/Slot
Mismatch Device
Not Found
175-
Configuration/Slot
Mismatch Device
Found
177-Configuration
Not Complete
178-Processor
Configuration
Invalid
180-Log
Reinitialized
201-Memory Error
202-Memory Type
Mismatch
203-Memory
Address Error
207-ECC
Corrected Single
Bit Errors in DIMM
in Memory Module
Socket
continued
Audible Beeps
Probable Source of
Problem
None
EISA or PCI board not
found.
None
EISA or PCI board
added, configuration
not updated.
None
Incomplete System
Configuration
detected.
None
Processor type or
step does not match
configuration
memory.
None
The IML has been
reinitialized, probably
due to corruption of
the log.
None
RAM failure
detected.
2 short
An incompatible
memory module is
installed in the
system.
None
RAM failure
detected.
2 short
A memory module is
malfunctioning.
Action
Run the server setup utility and correct.
Run the server setup utility and correct.
Run the server setup utility and correct.
Run the server setup utility and correct.
Event message, no action required.
Run Diagnostics. Replace failed
assembly as indicated.
Compare Compaq part numbers from
installed memory modules with the
manual.
If not listed, the memory modules are
incompatible and should be replaced or
removed.
Run Diagnostics. Replace failed
assembly as indicated.
Run Diagnostics. Replace or remove
malfunctioning memory module as
indicated.
continued