3-34 Compaq ProLiant ML350 Maintenance and Service Guide
Table 3-2
POST Error Messages
Error Code
1787-Drive Array
Operating in Interim
Recovery Mode.
Physical drive
replacement needed:
Drive X
*** 1788-Slot X Drive
Array Reports
Incorrect Drive
Replacement. The
following SCSI drive(s)
should have been
replaced: SCSI Port Y:
SCSI ID Z
The following SCSI
drive(s) were
incorrectly replaced:
SCSI Port y: SCSI ID z.
Select F1 to continue
– drive array will
remain disabled.
Select F2 to reset
configuration – all
data will be lost.
*** The 1788 error message might also be displayed inadvertently due to a bad power cable connection to the
drive, noise on the data cable, or a defective SCSI cable. If this message was due to a bad power cable
connection, but not incorrect drive replacement, repair the connection and press F2. If the message is not
eliminated by pressing F2, run Array Diagnostic Utility (ADU) to resolve.
-Or-
If this message was not due to a bad power cable connection, and no drive replacement took place, this could
indicate noise on the data cable. Check cable for proper routing.
-Or-
If this message is due to a defective SCSI cable, replace the cable.
continued
Audible Beeps
Probable Source
of Problem
None
Hard drive X failed
or cable is loose or
defective.
Following a system
restart, this
message reminds
you that drive X is
defective and fault
tolerance is being
used.
None
Drives are not
installed in their
original positions,
so the drives have
been disabled. See
note below.
Action
1.
Check for loose cables.
2.
Replace defective cables.
3.
Replace drive X as soon as
possible.
1.
Reinstall the drives correctly, as
indicated.
2.
Press F1 to restart the computer
with the drive array disabled.
-Or-
Press F2 to use the drives as
configured and lose all the data on
them.