3-60 Compaq ProLiant ML350 Maintenance and Service Guide
Table 3-19
ADU Diagnostic Messages
Message
Loose cable
detected –
logical drives
may be marked
FAILED until
corrected
Mirror data
miscompare
No configuration
for accelerator
board
NVRAM
configuration
present,
controller not
detected
RIS copies
between drives
do not match
SCSI Port x Drive
ID x has
exceeded
threshold(s)
SCSI Port x Drive
ID x is not
stamped for
monitoring
SCSI Port x Drive
ID x RIS copy
mismatch
SCSI Port x Drive
ID x failed –
REPLACE (failure
message)
SCSI Port x Drive
ID x firmware
needs upgrading
continued
Description
Controller unable to communicate
with one or more physical drives,
probably because of a cabling
problem. Logical drives may be in a
FAILED state until the condition is
corrected, preventing access to data
on the controller.
Data was found at reinitialization in
the posted write memory; however,
the mirror data compare test failed
resulting in data being marked as
invalid. Data loss is possible.
Array accelerator board has not been
configured.
EISA nonvolatile RAM has a
configuration for an array controller,
but there is no board in this slot.
Either a board has been removed
from the system or a board has been
placed in the wrong slot.
Drives on controller contain copies of
RIS that do not match.
Monitor and performance threshold
for this drive has been violated.
Drive has not been stamped with
Monitor and Performance features.
Copies of RIS on drive do not match.
ADU found drive that needs to be
replaced.
Drive firmware is below
recommended version.
Recommended Action
Check all controller and drive cable
connections.
Replace the array accelerator board.
If the array accelerator board is present, run the
Array Configuration Utility (ACU) to configure the
board.
Place the array controller in the proper slot or
run the BIOS Setup Utility to reconfigure
nonvolatile RAM to reflect the removal or new
position.
Upgrade ADU to the most recent version.
Check for the particular threshold that has been
violated.
Run the Array Configuration Utility (ACU).
Changing the configuration and saving should
cause ACU to stamp drive with Monitor and
Performance features. To do this without
destroying the current configuration, change
array accelerator size and save configuration.
Change the array accelerator back to original
size and save again.
Drive may need to be replaced. Check for other
errors.
Replace drive or correct condition that caused
error.
Run Options ROMPaq Utility to upgrade drive to
latest firmware revision.
continued