Table 3-2
POST Error Messages
continued
Error Code
Audible Beeps
611-Primary
2 short
Floppy Port
Address
Assignment
Conflict
800-Server
None
Feature Board
must be installed
in slot 1 for proper
operation
801-Server
None
Feature Board is
not properly
cabled to the
system. Verify that
the server
management
information cable
from the system
board to the
Server Feature
Board in slot 1 is
intact and fully
seated at both
ends
Probable Source of
Action
Problem
Hardware conflict in
1.
your system is
preventing the
diskette drive from
operating properly.
2.
System has detected
1.
the absence of the
Server Feature
2.
Board.
3.
Server Feature Board
is not installed in the
proper slot.
Server Feature Board
does not match this
system.
System has detected
1.
that the server
management
information cable is
2.
not properly
installed.
3.
Diagnostics and Troubleshooting 3-15
Run your server setup utility to
configure the diskette drive port
address and manually resolve the
conflict.
Run Diagnostics and replace failed
assembly as indicated.
Install the Server Feature Board in
PCI slot 1.
Reseat the Server Feature Board.
Verify that the Server Feature
Board is from this system.
Make sure a server management
information cable is installed in
the system.
Inspect the server management
information cable for signs of
damage.
Reseat the server management
information cable on the system
board and on the Server Feature
Board.
continued