Compaq ProLiant ML350 Maintenance And Service Manual page 87

Proliant ml350
Hide thumbs Also See for ProLiant ML350:
Table of Contents

Advertisement

3-32 Compaq ProLiant ML350 Maintenance and Service Guide
Table 3-2
POST Error Messages
Error Code
1785-Slot X Drive
Array not Configured
(followed by one of
the following):
Run Compaq Array
Configuration Utility
(ACU)
No drives detected
Drive positions appear
to have changed –
Run Drive Array
Advanced Diagnostics
if previous positions
are unknown. Then
turn system power
OFF and move drives
to their original
positions.
Configuration
information indicates
drive positions beyond
the capability of this
controller. This may
be due to drive
movement from a
controller that
supports more drives
than the current
controller.
Configuration
information indicates
drives were
configured on a
controller with a
newer firmware
version.
(RESUME = F1 KEY)
continued
Audible Beeps
Probable Source
of Problem
None
Drive array
configuration not
detected.
Action
Run the Array Configuration Utility (ACU).
Power down the system and check SCSI
cable connections to make sure drives
are attached properly.
Run Array Diagnostic Utility if previous
positions are unknown. Then power
down the system and move drives to
their original positions.
To avoid data loss, power down the
system and reattach drives to the
original controller.
To avoid data loss, reattach drives to the
original controller or upgrade the
controller firmware to the version on the
original controller using the Option
ROMPaq Utility.
Select F1 to resume.
continued

Advertisement

Table of Contents
loading

Table of Contents