Failure Detected; Not Present - Compaq ProLiant ML350 Maintenance And Service Manual

Proliant ml350
Hide thumbs Also See for ProLiant ML350:
Table of Contents

Advertisement

Table 3-2
POST Error Messages
continued
Error Code
Audible Beeps
1611-CPU Fan
None

failure detected

1611-CPU Fan not
None
present
1611-CPU Fan
2 short
(Fan X) failure
detected.
1611-Fan failure
2 short
detected.
1611-I/O Fan
None
failure detected
1611-I/O Fan not
None
present
1611-I/O Fan
2 short
(Fan X) failure
detected.
1611-System Fan
None
failure detected
1611-System Fan
None

not present

1612-Primary
2 short
power supply
failure.
Probable Source of
Action
Problem
Required fan not
1.
spinning.
2.
3.
Required fan not
1.
installed.
2.
3.
CPU fan has failed.
Replace the failed CPU fan.
Required fan not
Check fans.
installed or spinning.
Required fan not
1.
spinning.
2.
3.
Required fan not
1.
installed.
2.
3.
I/O fan has failed.
Replace the failed I/O fan.
Required fan not
1.
spinning.
2.
3.
Required fan not
1.
installed.
2.
3.
Primary power supply
Replace power supply as soon as
has failed.
possible.
Diagnostics and Troubleshooting 3-19
Check fans.
Reseat fan cable.
Replace fan.
Check fans.
Reseat fan cable.
Install missing fan.
Check fans.
Reseat fan cable.
Replace fan.
Check fans.
Reseat fan cable.
Install missing fan.
Check fans.
Reseat fan cable.
Replace fan.
Check fans.
Reseat fan cable.
Install missing fan.
continued