Compaq ProLiant ML350 Maintenance And Service Manual page 82

Proliant ml350
Hide thumbs Also See for ProLiant ML350:
Table of Contents

Advertisement

Table 3-2
POST Error Messages
continued
Error Code
Audible Beeps
1771-Primary Disk
None
Port Address
Assignment
Conflict
1772-Secondary
None
Disk Port Address
Assignment
Conflict
1773-Primary
None
Fixed Disk Port
Assignment
Conflict
1774-Slot X Drive
None
Array – Obsolete
data found in Array
Accelerator. Select
F1 to discard
contents of Array
Accelerator. Select
F2 to write
contents of Array
Accelerator to
drives.
Probable Source of
Action
Problem
Internal and external
Run the server setup utility and correct.
hard drive controllers
are both assigned to
the primary address.
Address Assignment
Run the server setup utility and correct.
Conflict. Internal and
external hard drive
controllers are both
assigned to the
secondary address.
Hard drive error
Run the server setup utility and correct.
detected.
SMART-2 Controller
Data found in array accelerator is older
error detected.
than data found on drives. Press F1 to
discard the older data in the array
accelerator and retain the newer data on
the drives.
Diagnostics and Troubleshooting 3-27