Compaq ProLiant ML350 Maintenance And Service Manual page 63

Proliant ml350
Hide thumbs Also See for ProLiant ML350:
Table of Contents

Advertisement

3-8 Compaq ProLiant ML350 Maintenance and Service Guide
Table 3-2
POST Error Messages
Error Code
ECC Multiple Bit
Error Detected in
DIMM:
FATAL ROM
ERROR: The
System ROM is
not properly
programmed.
Initialization
failure.
Re-seat the
processor and
Processor Power
Module before
attempting
replacement
Invalid electronic
serial number
No SCSI Devices
Detected
Non-System disk
or disk error
Parity Check 2
(RESUME – F1 key)
continued
Audible Beeps
Probable Source of
Problem
None
A memory module
failure generated a
multiple bit error that
could not be
corrected.
1 long, 1 short
The System ROM is
not properly
programmed.
None
Processor was not
fully seated.
A processor internal
failure occurred.
None
Serial number in
BIOS is incorrect.
None
No SCSI devices are
connected to the
boot controller.
None
No bootable disk
partition was found
on the boot drive.
None
A PCI device
generated a parity
error 2.
None
As indicated to
continue.
Action
Run Diagnostics and replace failed
memory module as indicated.
Flash the ROM or replace the physical
ROM part.
1.
Reseat the processor.
2.
Replace the processor if the failure
recurs.
Run server setup utility to program
serial number.
Verify configuration. Check SCSI cable,
attached drives, and SCSI IDs.
1.
Remove diskette from diskette
drive.
2.
Check controller order in server
setup utility.
3.
Check boot order in server setup
utility.
4.
Reinstall operating system.
Remove recently added PCI adapters.
Add the adapters again one at a time to
determine which is generating errors.
Replace the failed device.
Press F1.
continued

Advertisement

Table of Contents