Table 3-2
POST Error Messages
continued
Error Code
Audible Beeps
207-Invalid
None
Memory
Configuration –
Check DIMM
Installation
208-Invalid
1 long, 1 short
Memory Speed –
Check DIMM
Installation
209-Memory
1 long, 1 short
Detection Failure.
Check Memory
Installation
211-Invalid
None
Voltage Regulator
Module installed
for Processor X
212-System
1 short
Processor
Failed/Mapped out
214-DC-DC
None
Converter Failed
214-Memory
2 short
Device Failure.
Error Code:X
Memory Module
DIMM:Y
214-Processor
None
PPM Failed,
Module X
215-Processor
None
Power Module has
lost Redundancy
in Socket X
Probable Source of
Action
Problem
Memory module
Verify placement of memory modules.
installed incorrectly.
Speed of the
Verify the speed of the memory
memory is not
modules installed, then check the
compatible.
server user documentation and replace
as indicated.
Unable to size
Check memory module installation and
memory.
if error persists, call Compaq authorized
service provider.
Nonredundant PPM
Replace with a PPM that supports
installed in indicated
redundancy.
processor slot.
Processor in slot X
Run Diagnostics and replace failed
failed.
processor.
PPM failed.
Run Diagnostics. Replace failed
assembly as indicated.
A memory module
Run Diagnostics. Replace failed
has failed.
memory module as indicated.
Indicated PPM failed.
Replace failed assembly as indicated.
PPM (DC-DC
Run Diagnostics. Replace failed
converter) has lost
assembly as indicated.
redundancy.
Diagnostics and Troubleshooting 3-11