Removing DDR2 DIMMs
FIGURE 4-4
7. Place the DDR2 DIMM on an antistatic mat.
8. Repeat
4.1.4

Installing DDR2 DIMMs

Caution – Ensure that all power is removed from the server before removing or
installing DDR2 DIMMs, or damage to the DDR2 DIMMs might occur. You must
disconnect all power cables from the system before performing this procedure.
Tip – See
configuring the DDR2 DIMMs.
1. Unpackage the replacement DDR2 DIMMs and place them on an antistatic mat.
2. Ensure that the ejector tabs are in the open position.
3. Line up the replacement DDR2 DIMM with the connector (
Align the DDR2 DIMM notch with the key in the connector. This ensures that the
DDR2 DIMM is oriented correctly.
4-8
Sun Fire X4240 Server Service Manual • September 2010
Step 5
through
Step 7
Section 4.1.2, "DDR2 DIMM Guidelines" on page 4-4
to remove any additional DDR2 DIMMs.
for information about
).
FIGURE 4-5