5.8.3

Removing a PDB Cable

To remove a Power Distribution Board cable.
1. Prepare the server for service.
a. Power off the server.
b. Disconnect the power cord (or cords) from the power supply (or supplies).
c. Slide the server out of the rack.
d. Attach an antistatic wrist strap.
e. Remove the top cover.
2. Remove the air duct.
See
3. Remove the PDB end of the cable. (
a. Release the locking latches on either side and then pull the cable straight up.
b. Grasp each end of the connector on the motherboard, and then pull straight
5-26
Sun Fire X4240 Server Service Manual • September 2010
See
Section 2.5, "Powering Off the Server" on page
See
Section 2.5, "Powering Off the Server" on page
See
Section 2.6, "Extending the Server to the Maintenance Position" on
page
2-6.
See
Section 2.8, "Performing Electrostatic Discharge and Antistatic Prevention
Measures" on page
2-10.
See
Section 2.9, "Removing the Top Cover" on page
Section 4.2.1, "Removing the Air Duct" on page
up to disconnect from the connector.
2-4.
2-4.
2-12.
4-11.
)
FIGURE 5-16