c. Slide the server out of the rack.
See
Section 2.6, "Extending the Server to the Maintenance Position" on
page
2-6.
d. Attach an antistatic wrist strap.
See
Section 2.8, "Performing Electrostatic Discharge and Antistatic Prevention
Measures" on page
e. Remove the top cover.
See
Section 2.9, "Removing the Top Cover" on page
2. Press and hold the Remind button to identify which DDR2 DIMM is faulty.
(
)
FIGURE 4-1
3. Note the location of faulty DDR2 DIMMs.
Faulty DDR2 DIMMs are identified with a corresponding amber LED on the
motherboard.
4. Ensure that all DDR2 DIMMs are seated correctly in their slots.
If re-seating the DDR2 DIMM does not fix the problem, remove and replace the
faulty DDR2 DIMM.
Note – Refer to the Sun Fire X4140, X4240, and X4440 Servers Diagnostics Guide for
more information about DIMM System Event Log (SEL) messages.
2-10.
Chapter 4
2-12.
Servicing Motherboard Components
4-3