Removing The Air Duct - Oracle Sun Fire X4240 Service Manual

Table of Contents

Advertisement

Section 4.2.2, "Installing the Air Duct" on page 4-13
You must remove the air duct when removing and installing the following
components:
Power distribution board
Power supply unit (PSU) PDB
Paddle card
Motherboard
Note – CRU: This customer replaceable unit can be replaced by anyone.
Caution – To prevent the system from overheating, ensure that the air duct is
correctly installed before powering on the server.
4.2.1

Removing the Air Duct

1. Prepare the server for service.
a. Power off the server.
b. Disconnect the power cord (or cords) from the power supply (or supplies).
c. Slide the server out of the rack.
d. Attach an antistatic wrist strap.
e. Remove the top cover.
2. Slide the air duct to the right to disengage the left hand pin as shown in
FIGURE 4-6
3. Slide the air duct to the left to disengage the right hand pin.
4. Move the air duct towards the back to clear the lip on the midwall.
See
Section 2.5, "Powering Off the Server" on page
See
Section 2.5, "Powering Off the Server" on page
See
Section 2.6, "Extending the Server to the Maintenance Position" on
page
2-6.
See
Section 2.8, "Performing Electrostatic Discharge and Antistatic Prevention
Measures" on page
2-10.
See
Section 2.9, "Removing the Top Cover" on page
.
2-4.
2-4.
2-12.
Chapter 4
Servicing Motherboard Components
4-11

Advertisement

Table of Contents
loading

Table of Contents