2.6
Extending the Server to the Maintenance
Position
The following components can be serviced with the server in the maintenance
position:
Hard drives
SSDs
Fan modules
Power supplies
DVD/USB module
Fan power boards
DDR2 DIMMs
PCIe cards
Motherboard battery
If the server is installed in a rack with extendable slide rails, use this procedure to
extend the server to the maintenance position.
1. (Optional) Type the following command from the service processor (SP) prompt
-> to locate the system that requires maintenance.
-> set /SYS/LOCATE value=fast_blink
Locator indicator is on.
After you have located the server, press the Locator LED/Locator button to turn it
off.
2. Verify that no cables will be damaged or will interfere when the server is
extended.
Although the cable management arm (CMA) that is supplied with the server is
hinged to accommodate extending the server, you should ensure that all cables
and cords are capable of extending.
3. Extend the lower floor arm on the cabinet for safety, if present.
4. From the front of the server, release the two slide release latches (
Squeeze the green slide release latches to release the slide rails.
2-6
Sun Fire X4240 Server Service Manual • September 2010
).