3.3

CONTROL PCB INSTALLATION AND CONNECTION

The control PCB may be installed on either side of the furnace. Remove the 4 screws secured on the side of the
furnace where you wish to install the control PCB, either on the left or on the right side, and keep these screws.
Remove the access panel of the control PCB. Secure the control PCB where you removed the screws from the
furnace. Refer to the electric wiring diagram in section 7 for the electrical connections. Do not screw the access
panel back on the control PCB until all connections are made.
Control PCB installed on the RIGHT side of the furnace
Control PCB installed on the LEFT side of the furnace