GENERAL NOTES

This instructions manual treats mainly of the oil burning unit of your wood/oil combination furnace.
For any additional information concerning this wood burning furnace, please consult Section A of this manual.
To obtain the maximum efficiency out of your furnace, follow the advice below regarding the installation and operation
of your WOOD/OIL combination furnace.
Respect the local codes (when in doubt, consult your local dealer).
Respect the clearances indicated on this instructions manual and make sure that they match those indicated
on the appliance's certification label;
Make sure that your furnace is installed in conformity with the instructions on the certification label;
All the controls adjustments must be performed by a qualified technician.
THE INSTALLATION OF THE WOOD/OIL COMBINATION FURNACE MUST BE
DONE IN ACCORDANCE WITH THE RULES OF THE AUTHORITIES HAVING
JURISDICTION AND FOR CANADA, THE CAN/CSA B-139 STANDARD FOR OIL
BURNING HEATING APPLIANCES.
This oil burning furnace is not approved for use with combustible heavier than No.2 oil (furnace oil). DO
NOT USE GASOLINE, TRANSMISSION OIL, OR OTHER TYPE OF OIL CONTAINING GASOLINE.

1. DRAFT AND CHIMNEY

The chimney must be conform to the rules of the authorities having jurisdiction and the CAN/CSA B139 & NFPA 31
standard regarding installation of oil burning heating appliances. The installation of the connecting pipes to the oil unit
must be done and approved by a professional.
The barometric damper provided with the appliance must be properly installed on the flue pipe of the oil unit. The
purpose of the damper is to limit the draft, if necessary, in the oil unit evacuation pipe.
Since the evacuation pipe of the oil unit is connected to the evacuation pipe of the wood burning furnace, the
minimum draft to be respected at all times in the evacuation pipe of the wood burning side is -0.04 IN.W.C.
Also make sure to install the blocked-vent shut-off system (PA00600) in case of vent blocking.
49