FOR ADDITIONAL INFORMATIONS ON OPERATION SEQUENCES OF THE BURNER, CONSULT THE BURNER
INSTRUCTION MANUAL.
3.10

COMBUSTION ADJUSTMENT AND VERIFICATION

To enjoy the efficiency of our oil burning units, you must respect the following criterion:
Oil burning units must be connected to flue pipes having at all times a sufficient draft to ensure an efficient and safe
operation of unit.
Before turning on the oil unit, make sure that the sealed vision cap (SE53352) is installed and secured on the vision
tube with the screw provided. The chamber is calibrated so that there is a slight positive pressure, which optimizes the
efficiency of combustion. The presence of the sealed vision cap thus prevents the return of oil odor.
TOOLS REQUIRED:
-
DRAFT GAUGE
-
SMOKE TESTER
-
PUMP PRESSURE GAUGE
-
NOZZLE AND ELECTRODES POSITION TESTER
-
COMBUSTION TESTER
CHECK LIST:
-
SELECTION OF NOZZLE AND HEAD
-
NOZZLE / ELECTRODES POSITION IN RELATION TO THE HEAD
-
PUMP PRESSURE
-
OIL LINE IS BLEED.
-
FAN SPEED
-
BAROMETRIC DAMPER POSITION
54