Chapter 6: Engineering Mode; Using Engineering Mode; Engineering Mode Overview - Matrix T3X-02 Service Manual

Table of Contents

Advertisement

6.1 USiNG eNGiNeeriNG mode

1) To enter Engineering Mode, press & hold the INCLINE DOWN
and SPEED DOWN keys at the same time for 3-5 seconds until
Manager Mode appears on the display.
2) Press the INCLINE or SPEED keys until Engineering Mode
appears on the display (Figure A) and press ENTER.
3) To scroll between settings in the Engineering Mode, press the
INCLINE or SPEED keys.
4) Press ENTER to modify the settings once displayed.
5) Press any INCLINE or SPEED key to change the value of the
setting.
6) Once the setting is correct, press ENTER to save.
7) Press the EMERGENCY STOP to exit Engineering Mode..

6.2 eNGiNeeriNG mode oVerVieW

CUSTom SeTTiNG
defaUlT
Disable Errors
ON
Elevation Minimum
28
Elevation Maximum
230
Auto Calibration
N/A
Speed Units
MILE
Pause Time
30 SECONDS
Machine Type
N/A
Reset Defaults
N/A

CHaPTer 6: eNGiNeeriNG mode

miNimUm
ON
OFF
20
239
20
239
N/A
N/A
MILE
KILOMETER
5 SECONDS
10 MINUTES
N/A
N/A
N/A
N/A
fiGUre a
maximUm
UNiT
N/A
N/A
N/A
N/A
DISTANCE
SECOND / MINUTE
N/A
N/A
deSCriPTioN
Resets error log.
Accomplished by pressing
INCLINE DOWN and
SPEED DOWN for 3-5
seconds.
Controls the low incline
parameter.
Controls the high incline
parameter.
This function is to
calibrate the treadmill
incline.
Measurement unit used
for calorie calculations,
distance, and speed.
Controls the maximum
time the treadmill can be
paused during a workout.
Sets the machine ID, not
editable.
Reset the default values
to factory settings.