Chapter 6: Engineering Mode; Engineering Mode Overview; Engineering Mode - Calibration - Matrix T1XE-03 Service Manual

Table of Contents

Advertisement

6.1 ENGINEERING MODE OVERVIEW

The Engineering Mode allows the club owner to keep track of the technical settings and error history for the treadmill.
1) To enter Engineering Mode, press ENTER, 2, 0, 0, 1, ENTER on the number keypad ON THE CONSOLE. Engineering Mode will appear on
the display (Figure A).
2) Select the key next to the setting that needs to be changed, and follow the prompts to change.
3) Press the ENTER key once the desired setting is correct to save.
4) Press the key next to HOME on the display or press the EMERGENCY STOP key to return to normal operation.
6.2 ENGINEERING MODE - CALIBRATION TAB
ENGINEERING MODE
FUNCTION & DEFAULTS
Calibration
Auto Calibration
Incline Minimum
Default: 4000
Incline Maximum
Default: 29000

CHAPTER 6: ENGINEERING MODE

FIGURE A
This option calibrates the elevation parameters.
This option controls the minimum elevation
parameter.
This option controls the maximum elevation
parameter.
DESCRIPTIONS
MODIFIED
Range: 2500 - 12000
Range: 25000 - 32700
19