Chapter 6: Engineering Mode; Using Engineering Mode; Engineering Mode Overview - Matrix t3x-03 Service Manual

Table of Contents

Advertisement

6.1 USING ENGINEERING MODE

1) To enter Engineering Mode, press & hold the INCLINE DOWN
and SPEED DOWN keys at the same time for 3-5 seconds until
Manager Mode appears on the display.
2) Press the INCLINE or SPEED keys until Engineering Mode
appears on the display (Figure A) and press ENTER.
3) To scroll between settings in the Engineering Mode, press the
INCLINE or SPEED keys.
4) Press ENTER to modify the settings once displayed.
5) Press any INCLINE or SPEED key to change the value of the
setting.
6) Once the setting is correct, press ENTER to save.
7) Press the EMERGENCY STOP to exit Engineering Mode..

6.2 ENGINEERING MODE OVERVIEW

CUSTOM SETTING
DEFAULT
Disable Errors
OFF
Elevation Minimum
28
Elevation Maximum
230
Auto Calibration
N/A
Speed Units
MILE
Pause Time
5 MINUTES
Serial Number
Reset Defaults
N/A
Club ID
N/A
Audio Source
OFF
14

CHAPTER 6: ENGINEERING MODE

MINIMUM
MAXIMUM
OFF
ON
N/A
20
239
N/A
20
239
N/A
N/A
N/A
N/A
MILE
KILOMETER
DISTANCE
5 SECONDS 10 MINUTES
SECOND /
MINUTE
N/A
N/A
N/A
N/A
N/A
N/A
OFF
TV / PCTV /
N/A
REMOTE TV
FIGURE A
UNIT
Off - Shows Class A-C errors. On - Shows Class C errors
only.
Controls the low incline parameter.
Controls the high incline parameter.
This function is to calibrate the treadmill incline.
Measurement unit used for calorie calculations, distance,
and speed.
Controls the maximum time the treadmill can be paused
during a workout.
Serial Number input is available for both the Console and
Frame. Due to the limited LED characters, 2 layers are
used to enter the serial number. First Layer:
- PPPPP V
- PPPPP is the product name
- V is the version. If the version is A, just leave this blank.
Second Layer
- YY MM nnnnn.
- YY is the year (11, 12).
- MM is the month (e.g. 08, 09, 10).
- nnnnn is the actual serial number.
Use the UP / DOWN LEVEL keys to navigate the layers
and the number keys to input the serial number. The
product name is dependent on the Machine Type setting.
For example, the console is TM509 with ver. C and the
manufactured date is 2011.08 with 98765. The frame is
TM509 with ver. D and the manufactured date is 2011.06
with 12345. Their serial numbers are:
Console SN: TM509C 1rst layer, 110898765 2nd layer.
Frame SN: TM509D 1rst layer, 110612345 2nd layer.
Reset the default values to factory settings.
This sets the club ID for clubs using Asset Management.
Sets which outside TV will have audio through the console
audio ports.
DESCRIPTION