Compatible Racks

Use the slide rail kit to mount the server into the rack types listed below:
Sun Microsystems Sun Rack 900
Sun Microsystems Sun Fire Expansion Cabinet

To Rackmount the Server

1. Remove the inner glides from the slide assemblies. See
a. Press the release tabs on the catch at the end of the inner glide.
b. Run the glide out to the first stop.
c. Release the inner glide from the locked position by pulling the trigger on the
inside of the inner glide. See
a
Removing the Inner Glide from the Slide Assembly
FIGURE 2-1
Caution – When you operate the triggers to slide the server into and out of the
rack, move your fingers away from the trigger area once the server is released. There
is a pinch risk if you do not.
.
FIGURE 2-1
Chapter 2 Installing the Hardware
.
FIGURE 2-1
c
11