3. If you are prompted to do so, set a password for the admin user.
The password must:
Contain at least two alphabetic characters
■
Contain at least one numeric or one special character
■
Be at least six characters long
■
Once the password is set, the admin user has full permissions and can execute all
ALOM command-line interface (CLI) commands.
4. Turn on power to any peripherals and external storage devices you have connected
to the server.
Read the documentation supplied with the device for specific instructions.
5. At the console prompt, type the following command to power on the server:
sc> poweron
6. At the console prompt, type the following to access the server:
sc> console
To Power On Using the On/Standby Button
▼
Caution – Never move the system when the system power is on. Movement can
cause catastrophic hard drive failure. Always power off the system before moving it.
1. Connect the server to the power supply.
The server automatically goes into Standby power mode when it is connected to a
power source.
2. Turn on power to any peripherals and external storage devices you have connected
to the server.
Read the documentation supplied with the device for specific instructions.
3. Open the front bezel.
4. (Sun Fire V240 only) Insert the system key into the keyswitch and set it to the
Normal or Diagnostics position.
5. Press the On/Standby button.
18
Sun Fire V210 and V240 Servers Installation Guide • November 2005