Powering On the Server

To power on the server, you can use either the On/Standby button, located behind
the front bezel, or you can use the keyboard. Powering on from the keyboard
enables you to see system output as the server powers on.
Before you begin the procedures in this section, make sure that the keyswitch is in
the normal position. This position allows the On/Standby button to control the
power state of the server. For more information on the operation of the keyswitch,
see the Sun Fire V210 and V240 Servers Administration Guide.
The Sun Fire V210 server does not have a keyswitch.

To Power On From the Keyboard

1. Connect the server to the power supply.
The server automatically goes into Standby power mode when it is connected to a
power source.
2. Set up a connection to the SERIAL MGT port.
For details, refer to the Sun Fire V210 and V240 Servers Administration Guide.
When you switch to the ALOM prompt after initial power on, you will be logged in
as the admin user and prompted to set a password. You must set this password in
order to execute certain commands.
LED State
Network Speed Status
On
The network link is established and running at
its maximum supported speed.
Off
• If the network link indicator is on, the
network link is established but not running
at its maximum supported speed.
• If the network link indicator is off, network
link is not established.
Chapter 3 Powering On and Configuring the Server
17