The showhardconf output continued:
OPNL Status:Normal; Ver:0101h; Serial:PP082202R8
+ FRU-Part-Number:CA07082-D911 A1
PSU#0 Status:Normal; Serial:EA08210127;
+ FRU-Part-Number:CA01022-0720 02B
+ Power_Status:On;
PSU#1 Status:Normal; Serial:EA08210131;
+ FRU-Part-Number:CA01022-0720 02B
+ Power_Status:On;
FANBP_B Status:Normal; Ver:0101h; Serial:PP0821031E
+ FRU-Part-Number:CA20399-B12X 004AA/541-3304-01
FAN_A#0 Status:Normal;
FAN_A#1 Status:Normal;
XSCF>
For details, see the manual pages of showhardconf.
2. Confirm the state of the status LEDs of the FRU.
For information on the LED status, see
4.5
Cold Replacement/Cold Addition
In cold replacement, all business operations must be stopped. When accessing the
server, power off the server and disconnect the power cord to ensure safety.
For cold addition, do the same operation as that for cold replacement.
4.5.1
Powering off the Server
This section explains how to power off the server.
4.5.1.1
Power-off by Using the XSCF Command
1. Notify users that the server is being powered off.
2. Back up the system files and data to tape, if necessary.
3. Turn the mode switch on the operator panel to the Service position.
;
/541-3306-01
/300-2193-02
;
/300-2193-02
;
;
and
TABLE 2-3
TABLE 2-5
Chapter 4
FRU Replacement Preparation
;
;
.
4-11